Kamis, 25 Februari 2016

Isolating Converters

Isolating Converters

Industry Instrumentation

Process Instrumentation

Oil and Gas Industry

Ex-Applications





Photo

Type

Description

Measuring input

Documents

TV125L
Isolating Signal Converter
Outputs 0/2..10 V 0/4..20 mA, supply voltag 18..30 V
0/2..10 V, 0/4..20 mA,




TV500 / ST500


Isolating Signal Converter
Outputs 0/2..10 V 0/4..20 mA,
power feed converter,
Supply voltage 10.8..30 V AC/DC or 100..265 V AC
DIN rail mounting TS35
0/2..10 V, 0/4..20 mA,
transmitter supply

TV500Ex / ST500Ex


Isolating Signal Converter 
Outputs 0/2..10 V 0/4..20 mA,
Power feed converter,
Supply voltage 10..30 V AC/DC or 85..253 V AC
DIN rail mounting TS35
Inputs intrinsically safe
0/2..10 V, 0/4..20 mA,
transmitter supply

TV500H


Isolating Signal Converter
Output 0/2..10 V 0/4..20 mA,
with simulation function for engineering and maintenance without process interruption,
supply voltage 24 V DC or
230 V AC,
DIN rail mounting TS35
0/2..10 V, 0/4..20 mA,

TV500L


Isolating Signal Converter
Output 0/2..10 V 0/4..20 mA
or ±20 mA and ±10V,
increasing or decreasing characteristic curve,
supply voltage 24 V DC or
230 V AC,
DIN rail mounting TS35
0/2..10 V, 0/4..20 mA,
±10 V, ±20 mA

TV500P


Loop Powered Signal Converter
Output 4..20 mA passive,
loop voltage 14..30 V DC,
DIN rail mounting TS35
0/2..10 V, 0/4..20 mA,
±10 V, ±20 mA

TW500


Loop Powered Signal Converter
0(4)..20 mA,
1-3 channels in one case
DIN rail mounting TS35
0(4)..20 mA

TV501Ex


Isolating Signal Converter
Outputs 0/2..10 V 0/4..20 mA intrinsically safe,
burden max. 1000 Ohm,
supply voltage 10..30 V AC/DC or 85..253 V AC,
DIN rail mounting TS35
0/2..10 V, 0/4..20 mA
TS125 / 225
Isolating switching amplifier
supply voltage 20..125VDC and 20..250VAC
or 24V DC
switching contacts
Namur initiators
Optocouplers



TS500


Isolating Switching Repeater
Outputs: max. 2 channels
relay or transistor,
supply voltage 24 V DC or
230 V AC,
DIN rail mounting TS35
Proximity switch acc. to Namur
or switching contacts

TS500-Ex


Isolating Switching Repaeter
Outputs: max. 2 channels
relay or transistor,
supply voltage 24 V DC or
230 V AC,
DIN rail mounting TS35
Intrinsic safety inputs for proximity switch acc. to Namur and switching contacts

9001


Safety Barriers
for intrinsically safe mode for devices with signals Pt100 / Pt1000 or 0(4)..20 mA,
DIN rail mounting TS35
Pt100 / Pt1000 or
0(4)..20 mA

TSA-FIL
Standard Signal Converter, 3-way Isolation1 or 2 analog outputs,
plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35
Standard Signals
0..10, ± 10 V DC
0/4..20 mA


ASK-44A
4-Channel Signal Converter, 3-way IsolationAnalog outputs ±10 V at front panel, plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, 19" unit 5 / 8 TE
Standard signals
±10 V DC or ±20 mA, optional ±50 V or ±10 mV..±10 V via frame connector

ASK-44E
4-Channel Signal Converter, 3-way IsolationAnalog outputs ±10 V via frame connector, plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, 19" unit 5 / 8 TE
Standard signals
±10 V DC or ±20 mA, optional ±50 V or ±10 mV..±10 V at front panel

ASK-44D
4-Channel Signal Converter, 3-way IsolationDigital TTL outputs via front panel, supply voltage 24 V DC, 19" unit 8 TE
RS 422 signals
(4x2 tracks) via frame connector

ASK-DP 140, DP 200
1-Channel Signal Converter, Digital Isolation with 140 / 200 kHz Sample RateAnalog output ±10 V via front panel, plug-in filters 10 Hz..10 (20, 50) kHz, 4-pole Butterworth or Bessel characteristics, supply voltage ±15 V DC, 19" unit 5 TE
Standard signal
±10 V (optional ±20 mA) via front panel, range 10 mV, 1 V, 10 V selectable with rotary switch

ASK-8
8-Channel Signal Converter / DistributorAnalog outputs ±10 V via frame connector at common ground, plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage ±15 V DC, 19" unit 5 TE
Standard signals
±10 V DC via frame connector, optional gain 0.5..2

ASK-XYG-
                 VR
                  VT
Chassis and desktop housings19" technology
84 TE and
28, 63, 84 TE
Accomodation of ASK converter units
Provision of units with AC / DC power supply,
terminals for signal inputs and outputs also on back panel

SFIL
Plug-in Filter with ASK Cards for Interference SuppressionStandard frequencies 10, 30, 50, 100, 300, 500, 1k, 3k, 5k, 10k Hz, 4-pole Butterworth or Bessel characteristics
Conditioned signal ± 10 V

Tidak ada komentar:

Posting Komentar