Photo | Type | Description | Measuring Input | Documents |
|---|
CT500P
|
AC Current Transformer
1- or 2 channels,
analog output 4..20 mA,
arithmetic average measurement,
loop voltage 14..30 V DC,
DIN rail mounting TS35
|
0..1 A direct connection,
0..5 A via transformer
|
CT500
|
AC Current Transformeranalog output
0/2..10V, 0/4..20 mA, 12 measuring ranges selectable, true RMS measurement, supply voltage 10..30 V DC or 85..265 V AC, DIN rail mounting TS35 |
0..6 A direct connection,
0..60 A via internal current transformer
|
CVT500
|
AC Current and Voltage Transmitter
Analog output
0/2..10V, 0/4..20 mA,
arithmetic average value measurement, RMS calibrated,
supply voltage 24 V DC or
230 V AC,
DIN rail mounting TS35
|
Current
0..1 A/0..5A AC/DC
Voltage
0..125 V/0..250 V AC/DC |
VT500
|
AC Voltage TransformerAnalog output
0/2..10V, 0/4..20 mA, 6 measuring ranges selectable, true RMS measurement, supply voltage 10..30 V DC or 85..265 V AC, DIN rail mounting TS35 |
0..600 V direct connection
|
WM500
|
Active Power TransmitterAnalog output
0/2..10V, 0/4..20 mA, 1- and 3-phase power systems with symmetric load, compensation circuit,
supply voltage 24 V DC or 230 V AC,
DIN rail mounting TS35 |
Measuring voltage
0..100/440 V AC,
measuring current
0..1/5 A AC
|
AF500
|
Analog Frequency Transmitter
Teach-in Programming,
output frequence:
transistor 0..20 kHz
relay 0..10 Hz,
supply voltage 10..30 V DC or 85..265 V AC,
DIN rail mounting TS35
|
Analog input
0/2..10V, 0/4..20 mA
|
FT500
|
Frequency Analog Transformer
Analog output
0/2..10V, 0/4..20 mA,
supply voltage 10..30 V DC or 85..265 V AC,
DIN rail mounting TS35
|
Input frequence:
0..20 kHz
start and end value programmable,
transmitter supply
|
RT500
|
Resistance Transmitter
Analog output
0/2..10V, 0/4..20 mA,
increasing or decreasing output,
supply voltage 10..30 V AC/DC or 85..265 V AC,
DIN rail mounting TS35
|
Resistance range:
50 Ohm..100 kOhm
programmable,
transmitter supply
|
PMT50-1
|
Standard-Signal Transmitter with Profibus Interfacemax. 4 alarm outputs,
analog output, supply voltage 24 V DC, 115 V AC, 230 V AC, DIN rail mounting TS35 |
Standard-Signals
0/2..10 V DC or 0/4..20 mA, transmitter supply | |
PMT50EX-1
|
Standard-Signal Transmitter with Profibus Interface and Ex protectionmax. 2 alarm outputs,
analog output, supply voltage 24 V DC, 115 V AC, 230 V AC, DIN rail mounting TS35 |
Standard-Signals
0/2..10 V DC or 0/4..20 mA, transmitter supply |
TSA-FIL
|
Standard Signal Transmitter, 3-way Isolation1 or 2 analog outputs,
plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35 |
Standard Signals
0..10, ± 10 V DC 0/4..20 mA |
|
TSA-DMS
|
Strain Gauge Signal Conditioner, 3-way Isolation1 or 2 analog outputs,
plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35 |
Strain Gauge Bridges
2, 4, 10 mV/V switcheable |
|
TSA-Poti
|
Potentiometer Signal Conditioner, 3-way Isolation1 or 2 analog outputs,
plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35 |
Potentiometer 350..1000 Ω 3-/5-wire, 4 ranges 12.5, 25, 50, 100 %, switcheable
|
|
TSA-DC
|
Voltage Signal Conditioner, 3-way Isolation1 or 2 analog outputs,
plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35 |
DC or AC source
±10 V (± 20 mA) 4 ranges 0.15, 0.5, 1, 10 V switcheable |
|
TSA-Pt100
|
RTD Signal Conditioner, 3-way Isolation1 or 2 analog outputs,
plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35 |
Pt100 sensor
4-wire connection, choice of 1 fixed range -100..+100 °C, -100..+200 °C, -100..+500 °C |
|
TSA-TC
|
Thermocouple Signal Conditioner, 3-way Isolation1 or 2 analog outputs,
plug-in filters 10 Hz..5 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35 |
Thermocouples type J, K, T, R, ..
standard ranges -100..+100 °C, -100..+200 °C, -100..+500 °C, -100..+1000 °C, cable break LED |
|
TSA-ICP
|
ICP® Signal Conditioner, 3-way Isolation1 or 2 analog outputs,
plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35 |
ICP® sensors
standard gains 1, 2, 5, switchable, cable break LED |
|
TSA-RMS
|
RMS Signal Conditioner, 3-way IsolationAnalog output for (time) signal and RMS value,
plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35 |
Voltage source or ICP® sensors
gains switchable (depending on sensor type) |
|
TSA-MATH
|
Voltage Signal Combination, 3-way Isolation1 or 2 analog outputs,
plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35 |
Combination of 2 DC sources 0..10 V
with basic arithmetic operations: addition, subtraction, multiplication (power), division |
|
TSA-IF
|
Pulse Forming Signal Conditioning, 3-way IsolationTTL output (12 mA), optional open collector output 24 V, supply voltage 24 V DC, DIN rail mounting TS35
|
Frequency signals 0..50 kHz, 50 mVpp..60 Vpp
|
|
SFIL
|
Plug-in Filter with TSA Module for Interference SuppressionStandard frequencies 10, 30, 50, 100, 300, 500, 1k, 3k, 5k, 10k Hz, 4-pole Butterworth or Bessel characteristics
|
Conditioned signal ± 10 V
|
Messumformer LABO
General Information |
Photo | Type | Description | Measuring Input | Documents |
|---|
LABO-A-I-
U/F/C
|
Screw-in transmitter
Current output 4..20 mA
Voltage output 0..10 V
Frequency output
Pulse output
|
Metering range:
-500..+500 Gauss
|
LABO-A-S
|
Magnetic field switch
Push-Pull
(compatible to PNP/NPN)
|
Metering range:
-500..+500 Gauss
|
LABO-D...
I/U/F/C
|
Screw-in transmitter
pre-tensioned hall sensor
inductive-sensor
|
Signalausgang
4..20 mA
0..10 V
Frequenzausgang
Pulsausgang
|
LABO-D...S
|
Frequency swith
pre-tensioned hall sensor
inductive sensor
|
Push-Pull
(compatible to PNP/NPN)
|
LABO-W...I/U/F/C
|
Signal converter
Supply voltage:
10...30 V DC
|
Switching output:
Push-Pull |
LABO-W...S
|
Limit switch
Supply voltage:
10...30 V DC
|
Switching output:
Push-Pull |