Kamis, 25 Februari 2016

Safety and Monitoring Devices

MR50
Monitoring Relay
Max. 4 alarm outputs,
measuring range programmable,
supply voltage 24 V DC, 115 V AC, or 230 V AC,
DIN rail mounting TS35

Standard-Signals
0/2..10 V DC
0/4..20 mA,
transmitter supply
MR50Ex
Monitoring Relay with EX-protection
Max. 2 alarm outputs,
measuring range programmable,
supply voltage 24 V DC, 115 V AC, or 230 V AC,
DIN rail mounting TS35
Standard-Signals
0/2..10 V DC
0/4..20 mA,
transmitter supply

Safety and Monitoring Devices

Monitoring of AC Power systems

Temperature Limiter acc. to SIL2

Battery guard for solar systems and power stations

Insulation guard for health care facility´s and railway vehicles

Pressure monitoring, filling height

Live saving in machine controls for cutters, mixing machines etc.





Photo

Type

Description

Measuring input

Documents


MR50
Monitoring Relay
Max. 4 alarm outputs,
measuring range programmable,
supply voltage 24 V DC, 115 V AC, or 230 V AC,
DIN rail mounting TS35

Standard-Signals
0/2..10 V DC
0/4..20 mA,
transmitter supply
MR50Ex
Monitoring Relay with EX-protection
Max. 2 alarm outputs,
measuring range programmable,
supply voltage 24 V DC, 115 V AC, or 230 V AC,
DIN rail mounting TS35
Standard-Signals
0/2..10 V DC
0/4..20 mA,
transmitter supply

BW500


Battery Voltage Guard
Under-voltage/over-voltage,
DIN rail mounting TS35
12 V, 24 V, 48 V
or 60 V DC


GS500


Monitoring Relay
Min/Max function switch selectable
DIN rail mounting TS35
Standard-Signals
0/2..10 V, 0/4..20 mA


GS1000


Monitoring Relay
Min/Max function switch selectable,
max. 2 limit contacts,
Supply voltage 24 V DC, 24 V AC, 115 V AC, or 230 V AC
DIN rail mounting TS35
Standard-Signals
0..2.5 V/5 V/10 V, 0/4..20 mA,
Potentiometer


CVG500


Current and Voltage Monitoring Relay
Arithmetic average value measuring RMS calibrated (AC),
1 limit contact,
supply voltage 24 V DC 
or 230 V AC,
DIN rail mountingTS35
Voltage 0..125/250 V AC/DC
Current 0..1/5 A AC/DC


STL50
Safety Temperature Limiter
1 alarm output,
certified acc. to DIN EN 14597, SIL2,
supply voltage 24 V DC, 115 V AC or 230 V AC,
DIN rail mounting TS35

Pt100, Fe-CuNi, 
NiCr-Ni, NiCrSi-NiSi, Pt10Rh-Pt
STL50EX
Safety Temperature Limiter with Ex-protection
1 alarm output,
certified acc. to DIN EN 14597, SIL2,
supply voltage 24 V DC, 115 V AC or 230 V AC,
DIN rail mounting TS35
Pt100, Fe-CuNi, 
NiCr-Ni, NiCrSi-NiSi, Pt10Rh-Pt

Ci3

(DIN 96x96 mm)

Multipurpose Meter
Operation in 1- or 3-phase mains power systems,
1 Impuls output optional,
supply voltage 24 V DC or
230 V AC,
panel mounting
Voltage 100..500V AC,
Current 0..5 A AC,
via ext. current transformer


SD9648

(DIN 96x48 mm)

Alarm Display
LCD-Display
Supply voltage 24 V DC, 24 V AC, 115V AC or
230 V AC,
panel mounting
20 analog 0/4..20 mA or digital 0/24 V DC inputs


IW1000



Insulation Guard
for railway vehicles and healthcare facilities,
LCD-Display,
supply voltage 12, 24 V DC,
24 V, 115 V or 230 V AC,
DIN rail mounting TS35
Voltage 0..690 V AC,
frequency 16 2/3..400 Hz